Need a structural engineering in Auckland? BVT Engineering provides expertise in structural systems and earthquake engineering, with the latter being particularly relevant to seismically active Auckland. Call our friendly team for more information.

https://bvtengineering.com/

These two methods do slightly different things, however their features are relatively similar. 

The fix-float method is the quickest and easiest method to install as minimal additional materials are required, perimeter connections and seismic clips are all that is needed. Unfortunately this bracing method can only be used for small or lightweight ceilings as the seismic load increases with the overall ceiling weight causing the perimeter connections to become overloaded above a certain ceiling area.

When the fix-float methods are not an option, the ceiling must then be braced to the structure above. This is typically done through steel stud bracing. The bracing method is a lot more labour/ material intensive due to the additional braces and the time associated with installing them. The advantage of this method is that essentially all ceilings, no matter the size or weight, can be braced in this way. 

To read about these methods in further detail, please refer to our article about seismic bracing here.

https://bvtengineering.com/all-services/seismic-interior-engineering

Structural Engineering in Auckland Wide

1000 × 1464 — JPG 458.6 KB

6 年前にアップロード — 973 回

Need a structural engineering in Auckland? BVT Engineering provides expertise in structural systems and earthquake engineering, with the latter being particularly relevant to seismically active Auckland. Call our friendly team for more information.

https://bvtengineering.com/

These two methods do slightly different things, however their features are relatively similar.

The fix-float method is the quickest and easiest method to install as minimal additional materials are required, perimeter connections and seismic clips are all that is needed. Unfortunately this bracing method can only be used for small or lightweight ceilings as the seismic load increases with the overall ceiling weight causing the perimeter connections to become overloaded above a certain ceiling area.

When the fix-float methods are not an option, the ceiling must then be braced to the structure above. This is typically done through steel stud bracing. The bracing method is a lot more labour/ material intensive due to the additional braces and the time associated with installing them. The advantage of this method is that essentially all ceilings, no matter the size or weight, can be braced in this way.

To read about these methods in further detail, please refer to our article about seismic bracing here.

https://bvtengineering.com/all-services/seismic-interior-engineering

Customize upload by clicking on any preview
Customize upload by touching on any preview
コンピュータから参照 も使用できます。
アップロード中 0 files (0% 完了)
キューのアップロードが進行中です。完了まで数秒ほどかかります。
アップロード完了
アップロードが完了したコンテンツはに追加されました。 アップロードされたコンテンツに対してcreate new アルバムが可能です。
アップロードが完了したコンテンツはに追加されました。
このコンテンツをアカウントに保存するには、アカウントを作成 または サインイン である必要があります。
アップロードされたfileはありません。
Some errors have occurred and the system couldn't process your request.
    会員登録 で画像の自動削除、またはカスタマイズを可能にできます。
    または キャンセル残りも全てキャンセルする
    Note: Some files couldn't be uploaded. もっと詳しく
    詳しくはエラーレポートをご覧下さい。