Need a structural engineering in Auckland? BVT Engineering provides expertise in structural systems and earthquake engineering, with the latter being particularly relevant to seismically active Auckland. Call our friendly team for more information.

https://bvtengineering.com/

These two methods do slightly different things, however their features are relatively similar. 

The fix-float method is the quickest and easiest method to install as minimal additional materials are required, perimeter connections and seismic clips are all that is needed. Unfortunately this bracing method can only be used for small or lightweight ceilings as the seismic load increases with the overall ceiling weight causing the perimeter connections to become overloaded above a certain ceiling area.

When the fix-float methods are not an option, the ceiling must then be braced to the structure above. This is typically done through steel stud bracing. The bracing method is a lot more labour/ material intensive due to the additional braces and the time associated with installing them. The advantage of this method is that essentially all ceilings, no matter the size or weight, can be braced in this way. 

To read about these methods in further detail, please refer to our article about seismic bracing here.

https://bvtengineering.com/all-services/seismic-interior-engineering

Structural Engineering in Auckland Wide

1000 × 1464 — JPG 458.6 KB

Wysłano 6 lat temu — 973 wyświetlenia

Need a structural engineering in Auckland? BVT Engineering provides expertise in structural systems and earthquake engineering, with the latter being particularly relevant to seismically active Auckland. Call our friendly team for more information.

https://bvtengineering.com/

These two methods do slightly different things, however their features are relatively similar.

The fix-float method is the quickest and easiest method to install as minimal additional materials are required, perimeter connections and seismic clips are all that is needed. Unfortunately this bracing method can only be used for small or lightweight ceilings as the seismic load increases with the overall ceiling weight causing the perimeter connections to become overloaded above a certain ceiling area.

When the fix-float methods are not an option, the ceiling must then be braced to the structure above. This is typically done through steel stud bracing. The bracing method is a lot more labour/ material intensive due to the additional braces and the time associated with installing them. The advantage of this method is that essentially all ceilings, no matter the size or weight, can be braced in this way.

To read about these methods in further detail, please refer to our article about seismic bracing here.

https://bvtengineering.com/all-services/seismic-interior-engineering

Dostosuj ustawienia zdjęcia (tytuł, tagi, opis) klikając na dowolnej miniaturze
Dostosuj ustawienia zdjęcia (tytuł, tagi, opis) touching na dowolnej miniaturze
Wysyłanie 0 pliki (0% zakończono)
Kolejka jest przesyłana, jej ukończenie powinno zająć tylko kilka sekund.
Wysyłanie zakończone
Przesłana zawartość dodana do . You can stwórz nowy album with the content just uploaded.
Przesłana zawartość dodana do .
You must utwórz konto or zaloguj to save this content into your account.
Nie plik zostały przesłane
Wystąpiły pewne błędy i system nie mógł przetworzyć żądania.
    Zarejestruj się aby móc dostosować lub wyłączyć automatyczne usuwanie obrazów.
    lub anulujanuluj pozostałe
    Uwaga: niektórych plików nie można przesłać. dowiedz się więcej
    Sprawdź raport błędu, aby uzyskać więcej informacji.